王茁晨助理
姓名 | 王茁晨助理 |
性别 | 男 |
学校 | 天津大学 |
部门 | 发明专利包写包过 加急申请 |
学位 | 发明专利包写包过 特惠申请 |
学历 | 版权登记666包过 代写全部资料 |
职称 | 助理教授 |
联系方式 | 【发送到邮箱】 |
邮箱 | 【发送到邮箱】 |
人气 | |
软件产品登记测试 软件著作权666元代写全部资料 实用新型专利1875代写全部资料 集群智慧云企服 / 知识产权申请大平台 微信客服在线:543646 急速申请 包写包过 办事快、准、稳 |
王茁晨 教师名称:王茁晨 教师拼音名称:Wang Zhuochen 性别:男 职务:Assistant Professor 职称:助理教授 其他联系方式 邮编:300072 通讯/办公地址:Rm 326, Bldg 17, No. 92 Weijin Rd, Tianjin University, Tianjin, China 邮箱:zc_wang@tju.edu.cn 基本信息 研究方向 获奖情况 论文成果 Zhuochen Wang is originally from Tianjin, China, in 1984. He earned his B.S. degree in Mechanical Engineering from Tianjin University in 2005, and his M.S. degree in Mechanical Engineering from University of Akron in 2012. He completed his Ph.D. degree in Mechanical Engineering from North Carolina State University in 2016 with a focus on ultrasound transducer and imaging. Dr. Wang is currently an Assistant Professor in Tianjin University, School of Precision Instrument & Opto-electronics Engineering, State Key Laboratory of Precision Measuring Technology & Instruments. His research focuses on noval ultrasound technology development, particularly in the area of ultrasound transducer, medical ultrasound and nondestructive testing. Ultrasound transducers and arrays Medical ultrasound Nondestructive testing 暂无内容 1. Z. Wang, K. H. Martin, P. A. Dayton, X. Jiang, "Real-time ultrasound angiography using superharmonic dual-frequency (2.25 MHz / 30 MHz) cylindrical array: in vitro study", Ultrasonics, vol. 82, pp. 298-303, 2018..2017 2. Z. Wang, K. H. Martin, W. Huang, P. A. Dayton, and X. Jiang, "Contrast Enhanced Superharmonic Imaging for Acoustic Angiography Using Reduced Form-factor Lateral Mode Transmitters for Intravascular and Intracavity Applications", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 64, no. 2, pp. 266-274, pp. 311-319,2017. .2017 3. Z. Wang, S. Li, T. J Czernuszewicz, C. M. Gallippi, R. Liu, X. Geng, and X. Jiang "Design, fabrication and characterization of a bi-frequency co-linear array", IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol. 63, no. 2, pp. 266-274, 2016. .2017 7. Z. Wang, W. Huang, X. Jiang, K. H. Martin, and P. A. Dayton. "Dual-frequency IVUS array for contrast enhanced intravascular ultrasound imaging." in IEEE Int. Ultrason. Symp., 2015. .2017 4. Z An, Z Wang, H Li, X Jiang, Modeling of harmonic measurement radiated by a plane circular piston in fluids, IEEE SPAWDA, 2016..2017 5. S. Li, , J. Kim, Z. Wang, X. Jiang, S. Kasoji, B. Lindsey, and P. A. Dayton, A dual-frequency co-linear array for prostate acoustic angiography, IEEE Int. Ultrason. Symp., 2016..2017 6. Z. Wang, X. Jiang, T. J. Czernuszewicz, and C. M. Gallippi. "Dual-frequency IVUS transducer for acoustic radiation force impulse (ARFI) imaging." in IEEE Int. Ultrason. Symp., 2015. .2017 8. Z. Wang, K. H. Martin, P. A. Dayton, and X. Jiang. "A dual frequency IVUS transducer with a lateral mode transmitter for contrast enhanced intravascular ultrasound imaging", in ASME Int. Mech. Eng. Congress, 2015. .2017 9. S. Li, J. Kim, Z. Wang, X. Jiang, S. Kasoji, B. Lindsey, and P. A. Dayton; A 3 MHz/18 MHz dual-layer co-linear array for transrectal acoustic angiography; IEEE Int. Ultrason. Symp., 2015..2017 10. B. D. Lindsey, K. H. Martin, Paul A. Dayton, J. Ma, Z. Wang, and X. Jiang; Dual-frequency intravascular ultrasound imaging of microbubble contrast agents: Ex vivo and in vivo demonstration; IEEE Int. Ultrason. Symp., 2015..2017 11. Z. Wang, S. Li, X. Jiang, R. Liu and X. Geng, "Design and phantom testing of a bi-frequency co-linear array", in IEEE Int. Ultrason. Symp., pp. 2108-2111, 2014. .2017 12. Z. Wang, J. Ma, X. Jiang, K. H. Martin and P. A. Dayton, "An array transmitter for dual-frequency contrast enhanced intravascular ultrasound imaging", in IEEE Int. Ultrason. Symp., pp. 2104-2107, 2014. .2017 13. Z. Wang, S. Li, R. Liu, X. Geng, and X. Jiang. "A Bi-Frequency Co-Linear Array Transducer for Biomedical Ultrasound Imaging." in ASME Int. Mech. Eng. Congress, pp. V003T03A085, 2014. .2017 14. M. Wang, W. Yuan, X. Jiang, Y. Jing, and Z. Wang. "Disruption of microalgal cells using highfrequency focused ultrasound." Bioresource technology, vol. 153, pp. 315-321, 2014. .2017 15. T. J. Czernuszewicz, C. M. Gallippi, Z. Wang, J. Ma and X. Jiang; Acoustic radiation force (ARF) generation with a novel dual-frequency intravascular transducer; IEEE Int. Ultrason. Symp., 2014..2017 16. J. Ma, S. Li, Z. Wang, and X. Jiang; Anti-matching design for wave isolation in dual frequency transducer for intravascular super-harmonic imaging; ASME Int. Mech. Eng. Congress, 2014..2017 17. Z. Wang, S. Li, X. Jiang, R. Liu and X. Geng; Design, fabrication and characterization of a bi-frequency co-linear array (7.5MHz/15MHz); IEEE Int. Ultrason. Symp., 2013..2017 18. J. Ma, Z. Wang and X. Jiang; Design, fabrication, and test of a small aperture, dual frequency ultrasound transducer; SPIE Smart Structures and Materials, Nondestructive Evaluation and Health Monitoring, 2013..2017 19. Z. Wang and J. Zhe; Recent advances in particle and droplet manipulation for lab-on-a-chip devices based on surface acoustic waves; Lab on a Chip, vol. 11, 2011, pp. 1280–1285..2017 教育经历 2012.8-2016.12 North Carolina State University Mechanical Engineering Ph.D. 2010.1-2012.8 University of Akron Mechanical Engineering M.S. 2001.9-2005.7 Tianjin University Mechanical Engineering B.S. 工作经历 2017.10 -2019.12 |Tianjin University|Assistant Professor 2016.10 -2017.8 |Sonix|Tektronix, Inc|Technology Development Engineer 2012.8 -2016.10 |North Carolina State University|Research Assistant 2010.1 -2012.8 |University of Akron|Research Assitant 2006.6 -2009.12 |Tianjin Huayi Co., Ltd|Mechanical Engineer |